Vertical Transportation

 

Lifts
  • Schindler Lifts
  • Less than 30 seconds waiting time in average
  • Centralized passenger lift call system in main / individual floor lobbies 4 - 6 passenger lifts per lift zone
  • Two dedicated lifts with exclusive lobby serving 5,6,7/F of Tower 1
  • Passenger lifts with loading capacity of 1,600kg or 21 persons per lift
  • Service lifts with loading capacity of 1,000kg or 13 persons per lift
  • Lift speed of 4 mps for Low Zone Floors, 10mps for High Zone Floors
Mechanical  
Air-conditioning
  • Variable air volume (VAV)system
  • Individual temperature control for each VAV covering 300 - 450 sq ft
  • Wireless thermostats for open office areas available on request
  • Enthalpy control system regulating fresh air supply (one air change per hour per floor)
  • Additional air-conditioning zoning of less than 1,500 sq ft per zone,
  • 24-hour chilled water supply
  • Average cooling capacity of 180sf/Rtn (209w/ sq m)
Air Purging System
  • Allows quick and complete exchange of internal air with external fresh air
  • Reduces odors associated with fit-out of neighboring units
  • Preventative health measure
  • System performs at a rate of five air changes per 20 minutes per floor
Ventilation
  • Booster fan system in car park floors controlled by CO / CO2 temperature sensors